AQUATek LVA – Water Autosampler

The AQUATek LVA is a full automation solution for routine analysis of waters by purge and trap concentration.It utilizes a fixed volume loop that is filled with liquid sample, internal and/or surrogate standards are added, and then the sample is transferred to the Lumin or Stratum PTC. Upon completion of the purge step by the concentrator, the AQUATek LVA then initiates a clean up cycle where the sample loop and concentrator sparger are cleaned with 90°C water via the two-stage water heater.

Description

The AQUATek LVA is a full automation solution for routine analysis of waters by purge and trap concentration. It utilizes a fixed volume loop that is filled with liquid sample, internal and/or surrogate standards are added, and then the sample is transferred to the Lumin or Stratum PTC. Upon completion of the purge step by the concentrator, the AQUATek LVA then initiates a clean up cycle where the sample loop and concentrator sparger are cleaned with 90o C water via the two-stage water heater.
The AQUATek LVA offers all the capabilities you need for compliance with USEPA Methods for the analysis of aqueous volatile organic samples, including a true closed-system technique for sample handling and vial cooling. The closed-system sampling technique and vial chiller ensure the integrity of the sample during the sample preparation process, greatly minimizing volatile organics loss as well as reducing labor cost.

Applications

VOC sampling and analysis are used in a wide range of applications in the following industries:

  • Environmental
  • Food and Beverage
  • Pharmaceutical
  • Flavor and Fragrance
  • Petrochemical ​
  • Plastics and Polymers

Methods

USEPA 5030 in conjunction with 502.1, 502.2, 524.2, 524.3, 524.4, 503.1, 601, 602, 603, 624, 8010, 8015, 8020, 8021, 8030, 8240, and 8260​

ASTM and Standard Methods

Massachusetts VPH and GRO Methods

Specifications

Sample typeLiquids: drinking water and wastewater up to 15mm of sediment on bottom of 40mL vial.
TechniqueAutosampler using sample loops and 3-port solenoid valves with septum piercing needle. Used with Lumin Purge and Trap Concentrator
Vials84-positions for 40 mL VOA vials, single hole cap with PTFE-faced silicone septum, per USEPA specifications
Common MethodsUSEPA 5030, 502.1, 502.2, 524.2, 524.3, 524.4, 503.1, 601, 602, 603, 624, 8010, 8015, 8020, 8021, 8030, 8240, and 8260​, ASTM, Standard Methods, Massachusetts VPH, GRO Methods.
Liquid handlingGlass, PEEK, EPDM, Ultem for valve manifold; 1/16” OD PEEK tubing for liquid transfer.
Gas pathway1/16” and 1/8” OD PEEK tubing and 1/8” PTFE tubing
Sample precision<1% RSD (n=7 at 5 mL volumes measured by weight)
Water heaterVariable heat control form 40°C to 90°C
Standard injection
Volumes1,2,5,10 and 20 μL increments
Consumption1 μL per 1 μL injection
Vessels2x 15 mL standard vessel, UV protected and sealed under pressure.
Precision and accuracy<10% RSD measured by GC/MS for Fluorbenzene and Bromofluorbenzene (n=7 at 5 μL injection volume)
DimensionsHeight: 64,2 cm
Width: 54,8 cm
Depth: 66,8 cm
Weight31,75 kg
Gas RequirementsUltra-high purity (99,999%) Helium or Nitrogen at 60-100 psi
Communication InterfaceUSB
Power Requirements100-240 VAC +/- 10%, 50/60 Hz, 2.5A
Minimum Computer RequirementsOne free USB port
OptionsVial chiller to 4°C, Lumin Purge and Trap Concentrator